Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Chinese Medical Journal ; (24): 638-642, 2018.
Article in English | WPRIM | ID: wpr-690563

ABSTRACT

<p><b>Background</b>Total knee arthroplasty (TKA) is the most frequently performed procedure in treating advanced knee osteoarthritis. Excessive perioperative blood loss can sometimes lead to postoperative anemia. Tranexamic acid (TXA) is a potent fibrinolysis inhibitor which has been extensively used at the surgical incision and closure to lower overall blood loss in adult reconstruction surgery. Our previous study suggested that about two-thirds of the total blood loss (TBL) came from hidden blood loss (HBL) on postoperative days 1 and 2. The role of reducing HBL with TXA administration in postoperative TKA patients is unknown. The current study was designed to evaluate the efficiency and safety of supplemental intravenous (IV) TXA in further reducing HBL after primary TKA.</p><p><b>Methods</b>A prospective pilot study was conducted at a single institution on 43 consecutive patients who underwent unilateral TKA from September 2014 to February 2015. All patients were given 1 g of IV TXA 10-15 min before operation and another 1 g of IV TXA at the time of wound closure on the day of surgery. On postoperative days 1 and 2, the supplemental group (n = 21) was given additional 1 g of TXA intravenously twice a day, whereas the control group (n = 22) received an equal volume of saline. Drain output, hemoglobin (Hb), and hematocrit (HCT) were recorded preoperatively and 5 consecutive days postoperatively in both groups. HBL was calculated with the Gross formula. Pre- and post-operative lower extremity Doppler venous ultrasound was performed in all patients to detect deep vein thrombosis (DVT). The indexes were compared using the Mann-Whitney test, whereas the results of Hb and HCT were analyzed by repeated-measures analysis of variance. The difference was considered statistically significant if P < 0.05.</p><p><b>Results</b>The demographics and surgical characteristics of the two groups were comparable. Supplemental group had higher Hb level on postoperative days 1-5 compared to the control; however, the difference was not significant (F = 2.732, P = 0.106). The HCT of the supplemental group was significantly higher than that of the control group on postoperative day 5 (F = 5.254, P = 0.027). No significant difference was found in drainage volume and TBL, but the HBL was reduced in the supplemental group (supplemental 133.1 [71.8, 287.3] ml and control 296.0 [185.3, 421.4] ml, Z = 2.478, P = 0.013, median [interquartile range]). There was one DVT in the control group and none in the supplemental group. All patients were followed at 1 year after surgery, and no further complications were reported.</p><p><b>Conclusion</b>Based on the current study, additional doses of IV TXA could potentially further reduce HBL after primary TKA without increasing the risk of venous thromboembolism.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Arthroplasty, Replacement, Knee , Blood Loss, Surgical , Pilot Projects , Prospective Studies , Tranexamic Acid , Therapeutic Uses
2.
Chinese Medical Journal ; (24): 583-587, 2018.
Article in English | WPRIM | ID: wpr-341994

ABSTRACT

<p><b>Background</b>Restoring good alignment after total knee replacement (TKR) is still a challenge globally, and the clinical efficiency of patient-specific instruments (PSIs) remains controversial. In this study, we aimed to explore the value and significance of three-dimensional printing PSIs based on knee joint computed tomography (CT) and full-length lower extremity radiography in TKR.</p><p><b>Methods</b>Between June 2013 and October 2014, 31 TKRs were performed using PSIs based on knee joint CT and full-length lower extremity radiography in 31 patients (5 males and 26 females; mean age: 67.6 ± 7.9 years; body mass index [BMI]: 27.4 ± 3.5 kg/m). Thirty-one matched patients (4 males and 27 females; mean age: 67.4 ± 7.2 years; mean BMI: 28.1 ± 4.6 kg/m) who underwent TKR using conventional instruments in the same period served as the control group. The mean follow-up period was 38 months (31-47 months). Knee Society Score (KSS), surgical time, and postoperative drainage volume were recorded. Coronal alignment was measured on full-length radiography.</p><p><b>Results</b>Twenty-three (74.2%) and 20 (64.5%) patients showed good postoperative alignment in the PSI and control groups, respectively, without significant difference between the two groups (χ= 0.68, P = 0.409). The mean surgical time was 81.48 ± 16.40 min and 72.90 ± 18.10 min for the PSI and control groups, respectively, without significant difference between the two groups (t = 0.41, P = 0.055). The postoperative drainage volume was 250.9 ± 148.8 ml in the PSI group, which was significantly less than that in the control group (602.1 ± 230.6 ml, t = 6.83, P < 0.001). No significant difference in the KSS at the final follow-up was found between the PSI and control groups (91.06 ± 3.26 vs. 90.19 ± 3.84, t = 0.95, P = 0.870).</p><p><b>Conclusions</b>The use of PSIs based on knee joint CT and standing full-length lower extremity radiography in TKR resulted in acceptable alignment compared with the use of conventional instruments, although the marginal advantage was not statistically different. Surgical time and clinical results were also similar between the two groups. However, the PSI group had less postoperative drainage.</p>

3.
Chinese Medical Journal ; (24): 2535-2539, 2016.
Article in English | WPRIM | ID: wpr-230924

ABSTRACT

<p><b>BACKGROUND</b>A good postoperative alignment in total knee arthroplasty (TKA) is the key to achieving satisfactory results. We assessed the effect of femoral and tibial resection on the overall alignment after conventional TKA.</p><p><b>METHODS</b>We conducted a retrospective analysis of 212 primary TKAs in 188 patients. Intramedullary (IM)-guided resection was applied on the femoral side while extramedullary (EM)-guided resection was used on the tibial side. Using full-length X-ray, the preoperative femoral valgus angle and lower extremity alignment, as well as 2-week postoperative femoral and tibial prosthetic coronal alignment and overall lower extremity alignment, were measured.</p><p><b>RESULTS</b>Postoperatively, good prosthetic alignment was achieved in 191 cases (90.1%) on the tibial side and in 144 cases (67.9%) on the femoral side (χ2 = 5.441, P = 0.02). Multiple linear regression analysis was used to assess the effect of different alignment sides on the overall alignment in the coronal plane. Data were divided into five subgroups based on the valgus or varus status of the prostheses. The standardized regression coefficients of the femoral and tibial prosthetic alignment on the overall alignment were 0.666 and 0.414, respectively; in varus on both sides were 0.658 and 0.377, respectively; in valgus, 0.555 and 0.030; femoral side varus and tibial side valgus, 0.702 and 0.211; femoral side valgus and tibial side varus, -0.416 and 0.287. The study showed that the overall low extremity alignment was statistically influenced by the prosthetic alignment, except for the tibial prosthetic alignment when femoral prosthesis was in valgus (P = 0.153).</p><p><b>CONCLUSIONS</b>In conventional TKA, tibial side EM-guided resection may offer satisfactory postoperative alignment, and femoral resection relying on IM guide may lead to more undesirable results. Postoperative coronal alignment is mainly affected by the femoral resection. Therefore, femoral side operation should receive adequate attention from the surgeons.</p>


Subject(s)
Humans , Arthroplasty, Replacement, Knee , Methods , Asian People , Bone Malalignment , Femur , General Surgery , Postoperative Period , Retrospective Studies , Tibia , General Surgery
SELECTION OF CITATIONS
SEARCH DETAIL